Workingload of the cable holder for all types in kg | |||||||||||
High tensil cable, DIN EN 12385-4, 7x7, 2300 N / mm2 | |||||||||||
![]() - with TÜV / GS (safety factor 5) |
cable-ø in mm | ||||||||||
0,45 | 0,54 | 0,63 | 0,81 | 1,0 | 1,2 | 1,5 | 1,8 | 2,0 | 2,5 | 3,0 | |
10 | - | - | - | 8 | 11 | - | - | - | - | - | - |
12 | - | - | - | - | 13 | 16 | - | - | - | - | - |
15 | - | - | - | - | 13 | 16 | 25 | - | - | - | - |
18 | - | - | - | - | 12 | 20 | 29 | 34 | - | - | - |
18 S (six-ball-mechanism) |
- | - | - | - | 14 | 24 | 34 | 40 | - | - | - |
20 | - | - | - | - | 12 | 20 | 29 | 34 | 55 | - | - |
20 S (six-ball-mechanism) |
- | - | - | - | 14 | 24 | 34 | 40 | 66 | - | - |
25 | - | - | - | - | - | - | 24 | 42 | 56 | 68 | - |
30 | - | - | - | - | - | - | - | - | - | 70 | 85 |
30 S (six-ball-mechanism) |
- | - | - | - | - | - | - | - | - | 84 | 102 |
Stainless steel cable DIN EN 12385-4, 7x7, 1570 N / mm2 | |||||||||||
![]() |
cable-ø in mm | ||||||||||
0,45 | 0,54 | 0,63 | 0,81 | 1,0 | 1,2 | 1,5 | 1,8 | 2,0 | 2,5 | 3,0 | |
10 | 1,5 | 2,5 | 3,0 | 7 | 10 | - | - | - | - | - | - |
12 | - | - | - | - | 8 | 12 | - | - | - | - | - |
15 | - | - | - | - | 8 | 12 | 16 | - | - | - | - |
18 | - | - | - | - | 7 | 10 | 16 | 30 | - | - | - |
18 S (six-ball-mechanism) |
- | - | - | - | 8 | 12 | 19 | 36 | - | - | - |
20 | - | - | - | - | 7 | 10 | 16 | 30 | 38 | - | - |
20 S (six-ball-mechanism) |
- | - | - | - | 8 | 12 | 19 | 36 | 44 | - | - |
25 | - | - | - | - | - | - | 23 | 30 | 35 | 42 | - |
30 | - | - | - | - | - | - | - | - | - | 50 | 70 |
30 S (Sechskugler) |
- | - | - | - | - | - | - | - | - | 60 | 84 |
TÜV / GS
|
permitted cable construction / nominal tensil strength | |||||
6x7+1FE 1770 N/mm² |
6x7+1FE 1770 N/mm² |
6x19+FE 1770 N/mm² |
6x19+FE 1770 N/mm² |
6x19+FE 1770 N/mm² |
||
6x19+FE 1770 N/mm² |
6x19+FE 1770 N/mm² |
6x19+SE 1960 N/mm² |
6x19+SE 1770 N/mm² |
6x19+SE 1960 N/mm² |
||
6x37+FE 1770 N/mm² |
||||||
Cable-ø in mm / Working load in kg | ||||||
Cable Holder type | 4,0 mm | 5,0 mm | 6,0 mm | 6,35 mm | 8,0 mm | |
50 SV III | 120 | 180 | - | - | - | |
66 SV III | - | - | 270 | 300 | - | |
80 SV III | - | - | 270 | - | 480 |
DGUV instruction
|
permitted cable construction / nominal tensil strength | |||||
6x7+1FE 1770 N/mm² |
6x7+1FE 1770 N/mm² |
6x19+FE 1770 N/mm² |
6x19+FE 1770 N/mm² |
6x19+FE 1770 N/mm² |
||
6x19+FE 1770 N/mm² |
6x19+FE 1770 N/mm² |
6x19+SE 1960 N/mm² |
6x19+SE 1770 N/mm² |
6x19+SE 1960 N/mm² |
||
6x37+FE 1770 N/mm² |
||||||
Cable-ø in mm / Working load in kg | ||||||
Cable Holder type | 4,0 mm | 5,0 mm | 6,0 mm | 6,35 mm | 8,0 mm | |
50 SV III | 60 | 90 | - | - | - | |
66 SV III | - | - | 135 | 150 | - | |
80 SV III | - | - | 135 | - | 240 |