Working loads
DGUV Vorschrift 17
|
Permissible cable construction / Cable grade | |||||
| 6x7-FC / WSC 1770 - 1960 |
6x7-FC / WSC 1770 - 1960 |
6x7-FC / WSC 1770 - 1960 |
6x7-FC / WSC 1770 - 1960 |
6x19M-FC 1770 - 1960 |
||
| 6x19M-FC / WSC 1770 - 1960 |
6x19M-FC / WSC 1770 - 1960 |
6x19M-FC / WSC 1770 - 1960 |
6x19M-FC / WSC 1770 - 1960 |
6x19M-WSC 1770 - 1960 |
||
| 6x37M-FC 1770 - 1960 |
||||||
| Load capacity / Working load / WLL in Kg - (Safety factor 10) | ||||||
| Type | Identification | Cable Ø 4,0 mm | Cable Ø 5,0 mm | Cable Ø 6,0 mm | Cable Ø 6,35 mm | Cable Ø 8,0 mm |
| 50 | 50 SV III | 60 kg | 90 kg | - | - | - |
| 66 | 66 SV III | - | 90 kg | 135 kg | 150 kg | - |
| 80 | 80 SV III | - | - | 135 kg | 150 kg | 240 kg |
TÜV / GS
|
Permissible cable construction / Cable grade | |||||
| 6x7-FC / WSC 1770 - 1960 |
6x7-FC / WSC 1770 - 1960 |
6x7-FC / WSC 1770 - 1960 |
6x7-FC / WSC 1770 - 1960 |
6x19M-FC / WSC 1770 - 1960 |
||
| 6x19M-FC / WSC 1770 - 1960 |
6x19M-FC / WSC 1770 - 1960 |
6x19M-FC / WSC 1770 - 1960 |
6x19M-FC / WSC |
6x37M-FC |
||
| 6x19-WSC 6x7-WSC 1570 |
6x19-WSC 6x7-WSC 1570 |
6x19-WSC 6x7-WSC 1570 |
6x19-WSC 6x7-WSC 1570 |
|||
| Load capacity / Working load / WLL in Kg - (Safety factor 5) | ||||||
| Type | Identification | Cable Ø 4,0 mm | Cable Ø 5,0 mm | Cable Ø 6,0 mm | Cable Ø 6,35 mm | Cable Ø 8,0 mm |
| 50 | 50 SV III | 120 kg | 180 kg | - | - | - |
| 66 | 66 SV III | - | - | 270 kg | 300 kg | - |
| 80 | 80 SV III | - | - | 270 kg | - | 480 kg |
- The loads indicated on the SV II nameplates (on wire rope holders) are not valid, the working loads from the table apply
- Further technical / safety information can be found in the operating instructions